AIMEAssociation of Energy Infrastructure Maintenance

The rules

Operator qualification, as written.

What 49 CFR Part 192 Subpart N and Part 195 Subpart G require, what PHMSA has said about them, and the consensus standards built on them. Gas and liquid rules are parallel; section numbers are given for both.

Federal rule

Eight requirements.

  • §§ 192.801(b), 195.501(b)

    Covered task

    An activity, identified by the operator, that is performed on a pipeline facility, is an operations or maintenance task, is performed as a requirement of Part 192 or 195, and affects the operation or integrity of the pipeline. PHMSA and the standards call this the four-part test.

  • §§ 192.803, 195.503

    Qualified

    An individual has been evaluated and can perform assigned covered tasks and recognize and react to abnormal operating conditions.

  • §§ 192.803, 195.503

    Abnormal operating condition

    A condition, identified by the operator, that may indicate a malfunction or deviation from normal operations that may indicate a condition exceeding design limits or result in a hazard to persons, property, or the environment.

  • §§ 192.803, 192.809, 195.503, 195.509

    Evaluation

    A process established and documented by the operator: written or oral examination, work performance history review, observation during performance on the job, on-the-job training or simulations, or other forms of assessment. Since 2002, work performance history may not be the sole method. Since December 16, 2004, observation of on-the-job performance may not be the sole method.

  • §§ 192.805(c), 195.505(c)

    Span of control

    An individual who is not qualified may perform a covered task only if directed and observed by an individual who is qualified. The rule sets no ratio. Each operator sets its own, and PHMSA treats an increase in a span-of-control ratio as a significant program change that must be reported.

  • §§ 192.805(g), 195.505(g)

    Requalification intervals

    The operator identifies the covered tasks and the intervals at which each individual must be re-evaluated. The rule sets no interval. PHMSA guidance says intervals may reflect task difficulty, importance, and how often the task is performed.

  • §§ 192.805(d)–(f), (h), 195.505(d)–(f), (h)

    Re-evaluation, changes, training

    The operator must re-evaluate an individual whose performance may have contributed to an incident or accident, or who may no longer be qualified; communicate changes that affect covered tasks; and provide training as appropriate.

  • §§ 192.807, 195.507

    Records

    Qualification records must identify the individual, the covered tasks, the dates of current qualification, and the qualification method. They are kept while the individual performs the task, and for five years after.

Contractors

The operator answers for every individual.

From PHMSA's published OQ guidance.

  • Contractors are not required to have their own written OQ program. The operator must ensure that every individual performing covered tasks on its system, employee or contractor, meets the operator's program.
  • The operator must verify and document that a contractor's qualifications satisfy the operator's written program, and must keep qualification records for contractor personnel.
  • Contractors follow the operator's written procedures. An operator may adopt a contractor's procedure only after reviewing and approving it.
  • An operator using an off-the-shelf OQ program remains fully responsible for making it fit its own operating characteristics, procedures, and equipment.

PHMSA has also stated that observation alone, without interaction, does not adequately measure knowledge and skill, does not measure the ability to recognize and react to abnormal operating conditions, and is not an adequate sole method for any covered task.

Standards

The consensus documents.

  • ASME B31Q-2025

    Pipeline Personnel Qualification, an American National Standard covering gas and liquid pipelines. It sets requirements for identifying covered tasks, AOCs, training, evaluation, qualification, program effectiveness, and documentation, with a nonmandatory Integrated Task List. Section 10 addresses portability of qualifications. The next edition is scheduled for 2027.

  • API RP 1161, 6th edition (2025)

    Recommended Practice for Hazardous Liquid Pipeline Operator Qualification, written to Part 195 Subpart G. It includes a recommended covered task list with task standards, guidance on span of control and evaluation intervals, and AOC guidance. API states it is intended for operators, training providers, vendors, and regulators.

Public record

What investigations have found.

National Transportation Safety Board findings on qualification for covered tasks.

The program.

How AIME's work fits inside these rules and standards.